EMG EP System
Model:
Minimum order:
Wheelbase:
Weight:
Function:
Introduction:
The equipment records bioelectricity activity of nerve muscle for determining its function state, which combines with nerve conduction speed, to give patient an auxiliary diagnosis. Checking contents: EMG(electromygram), MCS(motor nerve conductor velocity), SCS(sensory nerve conductor velocity), F wave, Hreflex, RNS(repetitive nerve stimulation), Blink Reflex, VEP(visual evoked potential), BAEP(brainstem auditory evoked potential), SEP(somatosensory evoked potential), etc
Features:
· Professional EMG/EP operation platform and perfect test items, complete each test in the shortest time.
· Neuro and muscle navigation system, convenient in selecting test part.
· Powerful normal values system, contrast with normal data automatically.
· Flexible software design, configure system parameters according to requirements.
· High-speed data collection, electromagnetic interference suppression, Photoelectric isolation and low noise.
· Integrative hardware system, compact in configuration and easy in moving.
Performance:
Main system part
A/D conversion resolution 16 Bit
Sampling ratio 200kHz
Analysis time 5-5000ms
Stimulating frequency 0.1-50Hz
Amplifier part
Four-channel
Sensitivity 0.05μV-20mV/Grid
Earth noise EMG <= 4μV(Vpp)
EP <=0.1μV(Vpp) (1000 times in average)
Common-mode rejection ratio >= 100dB
50Hz Ban wave setting:
Upper limit for Filter-frequency 20kHz
Lower limit for Filter-frequency 1Hz
Gain amplifies 25 times-400000 times
Stimulator part
Constant current 0.2-100mA
Pulse width 50-1000μS
Short circuit and overloading protection
Auditory Stimulator
Stimulation wave 40Hz Short, Sound Stim
Stimulation polarity nondense wave, dense wave and alternant wave.
Sound strength 40-120db (5db per level)
Stimulation mode left, right, left & right
Frequency of 40Hz carrier wave 500-8000Hz
Visual stimulator
Mode tessellation, horizontal bar and vertical bar.
Stimulation view all-view, half-view and quarter-view
Resolution 3x4, 6x8, 12x16, 24x32, 48x64
Flash stimulator all quench,left light,right light,l&r light
Physical characteristic:
Dimension 420mm*350mm*46mm(L×W×H)
Net weight 6KG
Accessories:
1. Disk
2. Power Cord
3. Power Adapter
4. USB Cable
5. Audio Cable
6. Earth Cable
7. Current Stimulator
8. One-off Bipolar Needle Electrode D039035408, 0.35*40mm, D039060706, 0.60*70mm
9. Reuseable Bipolar Needle Electrode R039035408, 0.35*40mm, R039060706, 0.60*70mm
10. Concentric Needle Connecting Wire
11. 1mm Connecting Lead Wire
12. Disc Electrode
13. Ring Electrode
14. Surface Electrode
15. Ground Electrode(Include lead cable)
16. One-off Unipolar Needle Electrode
17. From 1 to 2 Conversion Cable
18. Surface Electrode Conversion Cable
19. Fuse 0.1A/250V, 5*20mm
20. Fuse F1.6AL250V, 5*20mm
21. Flash Stimulator
22. Audio Stimulator
Send Inquiry