Contec12-channel ECG Machine
Model: ECG1200G
Minimum order:
Wheelbase:
Weight:
Function: 12-Channel ECG1200G Electrocardiograph Portable Ecg Heart Monitor with PC Software CE FDA approved
1) Sync collection for 12-lead ECG, adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.
2) Display of 3/6/12-lead ECG, print mode, sensitivity, paper speed and filter state, etc. on one screen, convenient for contrastively diagnosing.
3) Multiply printing modes and formats, including auto 12x1, auto 6x2+1, auto 6x2+1_H, auto 6x2, auto 6x2_H, auto 3x4+1, auto 3x4+2, rhythm 12, rhythm 10, rhythm 8, rhythm 6, manual, etc. Trend chart and histogram of P-R interval can be printed, waveform length printed can be adjusted, and with time print function, which meets different requirements.
4) Paper speed: 5mm/s, 6.25mm/s, 10mm/s, 12.5mm/s, 25mm/s, 50mm/s.
5) With the functions of auto-analysis and auto-diagnosis for routine ECG parameters, provide measurement results and auto-diagnosis conclusion for HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1), etc. which reduces the doctor's burden.
6) Built-in memory stores up to 1000 cases, convenient for case review and statistic.
7) Multi-language(Turkish, French, Chinese, English, German, Kazakstan, Polish, Portuguese, Russian, Slovenian, Spanish and Ukrainian) interface and report.
8) In optimal DC state, up to 10-hour standby time, continuous print more than 3-hour, record up to 300 ECG waveform(commonly, it is 3s case), which meets the requirements of visiting a patient at home and body examination.
Physical Specification
Input mode | Floating and defibrillation protection |
Frequency response | 0.05Hz ~ 150Hz(-3dB~+0.4dB) |
CMRR | >60dB, >100dB(add filter) |
Time constant | ≥ 3.2s |
Patient leak current | <10µA |
Calibration voltage | 1mV |
Sensitivity | 2.5, 5, 10, 20, 40 mm/mV ±5% |
Standard sensitivity | 10mm/mV±2% |
Noise level | ≤15µVp-p |
Input circuit current | ≤50nA |
Input impedance | ≥50MΩ |
Sampling accuracy | 12-bit |
Safety classification | class I, type CF and defibrillation-proof applied part |
Recording mode | thermal printing system |
Paper size | 210mm(W)×20m(L) |
Sampling frequency | 1000Hz |
EMG interference filter | 25Hz/35Hz (-3dB) |
Power frequency filter | AC 50Hz/60Hz(-20dB) |
Paper speed | Auto: 25, 50mm/s, ±5% |
Rhythm: 25, 50mm/s, ±5% | |
Manual: 5, 6.25, 10, 12.5, 25, 50mm/s, ±5% | |
Auto record | set record according to auto record format and mode, automatically switching leads, measuring and analyzing. |
Rhythm record | set record according to rhythm record format and mode, automatically measuring and analyzing. |
Manual record | set record according to record format, manually switching leads. |
Measurement parameters | HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1) |
Power supply | AC: 100V~240V(50/60Hz) |
DC: 14.8V/3500mAh rechargeable lithium battery | |
Fuse specification | two AC time lag fuse(φ5×20mm), T1.6AL250V |
Waterproof degree | IPX0 |
Working mode | continuous working |
Standard Package
Standard: | Optional: |
-A lead cable | -ECG-Sync software+USB cable |
Send Inquiry